Radio Type Approval, Homologation, Certification Services - Global Market Access Solutions
We can offer you reliably all services concerning Type Approval in Hong Kong (). Our distinguished contact with the authority in Hong Kong (), our good relationship to Office of the Telecommunications Authority (OFTA) as well as the qualification in the homologation of consumer and automotive RF-products and Short Range Devices (SRD) in ISM-Frequency band will create your market access in Hong Kong trouble-free and cost-effective.
We will assist you to put your product successfully on the market by offering the following services:
Identify applicable requirements for your specific product or technology feature to comply with current regulations in safety, EMC, wireless, etc.
Provide pre-compliance testing during the design and development phase to determine compliance
Assist in completion of applications and other required forms
Test in our accredited labs or your qualified facilities to issue CB Test Report and Certificate with applicable national differences and other test reports for wireless, etc.
Handle entire submittal process including working with local testing and certification organizations
Arrange for initial factory inspections that are required before certification issuance
Coordinate verification testing on qualified products as needed
Facilitate and expedite project progress with support of IB-Lenhardt AG local team and/or partner
Support renewal maintenance of certificates as needed
User manual translation service when needed
For Hong Kong we can offer you a short termed tentative offer based upon a submitted Datasheet of the device: quote@ib-lenhardt.de
Marking of Certification Logo or Number Required?
No
Size
mm
Specific User Manual Requirements?
No
News for Hong Kong
OCFA published a new Table of Frequency Allocations
In January 2021, Hong Kong's Office of the Communications Authority (OFCA) published a new Table of Frequency Allocations which replaces the version from April 2020.
The plan complies with the Region 3 allocations under the Radio Regulations which are applicable to Hong Kong, the allocations which have been adopted by Hong Kong, as well as the band plans in use in Hong Kong.
The detailed changes which emerge from this regulation can be found on the OFCA website:
OFCA assigned 24-28 GHz bands
Hong Kong’s Office of the Communications Authority (OFCA) of Hong Kong has assigned 24-28 GHz bands to mobile operators.
There are two standards:
Type Acceptance Criteria for 5G New Radio Base Station Equipment operating in the 24.25 - 28.35 GHz Band
Type Acceptance Criteria for 5G New Radio User Equipment operating in the 24.25 - 28.35 GHz Band.
New radio user equipment must fulfill:
Electrical Safety Requirements pursuant to HKCA 2001 “Compliance Test Specification – Safety and Electrical Protection Requirements for Subscriber Telecommunications Equipment”.
Radio Frequency Safety Requirements applicable to public pursuant to Title 47, Chapter 1, Part 30, Subpart С, Section 30.207 of Code of Federal Regulations of USA.
Operating Frequencies are as follows:
Transmitting: 24.25 – 28.35 GHz
Receiving: 24.25 – 28.35 GHz
Technical requirements are stated in TS 38.521-2 titled “Third Generation Partnership Project; Technical Specification Group Radio Access Network; NR; User Equipment (UE) conformance specification; Radio transmission and reception; Part 2: Range 2 Standalone (Release 15)” published by the Third Generation Partnership Project (3GPP). Compliance of the equipment with the technical requirements must be evaluated in accordance with the procedures specified in this 3GPP specification.
New radio base station equipment must fulfill:
Operating Frequencies are as follows:
Transmitting: 24.25 – 28.35 GHz
Receiving: 24.25 – 28.35 GHz
2. Technical requirements are stated in TS 38.141-2 titled “3rd Generation Partnership Project; Technical Specification Group RAN; NR; Base Station (BS) Conformance Testing, Part 2: Radiated Conformance Testing (Release 15)” published by the Third Generation Partnership Project (3GPP). Compliance of the equipment with the technical requirements must be evaluated in accordance with the procedures specified in this 3GPP specification.
Description
The Type G electrical plug has three rectangular blades in a triangular pattern and has an incorporated fuse (usually a 3 amps fuse for smaller appliances such as a computer and a 13 amps one for heavy duty appliances such as heaters). British sockets have shutters on the live and neutral contacts so that foreign objects can’t be introduced into them.
Netzspannung
220V
Netzfrequenz
50Hz
Description
The Type D electrical plug has three large round pins in a triangular pattern. Type M plugs are often used alongside Type D plugs for larger appliances and as a result, some sockets work with both Type D and Type M plugs. Type D plugs are rated 5 amps.
Contact
Pascale Müller