Power Density & Field Level (Far Field)

Use this tool to calculate the radiated field strength (in V/m) based on amplifier power, antenna gain, and distance.

W
dBi
m
Result: 0 V/m

Formula: E = √(30 × P × G) / d

Where:

  • E = Field strength (V/m)
  • P = Power (W)
  • G = Gain (from dBi)
  • d = Distance (m)

This tool assists in:

  • Field strength compliance: Verifying that your setup complies with immunity standards for electromagnetic compatibility (EMC).

  • Optimizing RF test setups: Identifying the appropriate power amplifier and antenna combinations to meet specific testing requirements.

  • Safety and EMI evaluation: Assessing potential radiation hazards or electromagnetic interference (EMI) risks in different environments.

Last updated on May 6, 2025 by IBL-Editors Team Give feedback on this article